* Coupling torque (output) calculation of bridge drive (Indoor EOC)
* Bridge drive motor power : Pu = kw x set
* Bridge drive motor rpm : N = rpm
* Bridge drive reducer gear ratio : i = 1/
* Service factor : Sf = (% of motor torque)
* Used coupling allowable torque : Tu = kg.m/set
* Required coupling torque
( Calculated value )
* Required coupling torque Tc = kg.m < Tu = kg.m/set